Inverter Industrial - APV 55k/65k-TL

The components of the Radius 55/65k have been developed to have a service life of at least 25 years and ensure high-level efficiency.

The intelligent "Maximum Power Point Tracking" algorithm picks up the maximum power from the modules under all operating conditions, within a wide range of temperatures and a wide DC input voltage range.

The Radius 55/65k operates at temperatures of up to 50°C without power derating and at a maximum voltage of 1000 Vdc to optimise plant design and reduce DC wiring between strings to a minimum.

Gefran also offers “transformerless” (TL) versions for multi-inverter systems. In that case the plant comprises a single grid output transformer. The elimination of dedicated transformers improves plant performance for maximum efficiency.

Grid connection certifications
Italy: DK5940; Germany, France, Turkey, Greece and Czech Republic: DIN V VDE V 0126-1-1 (VDE V 0126-1-1):2006-02; Spain: RD 1663:2000; UK: G59/1:1991, G59/2:1991; Belgium: C10/11:2006; Israel AS 4777.2:2005, AS 4777.3:2005.

Contact usFor more information
Choose language:
  APV55k-T APV65k-TL
DC INPUT
Recommended maximum PV power Pdc, max [kW] 64.7 (1) 76 (1)
MPPT voltage range Udc [V] 465...850 483...850
Minimum operating voltage Udc min [V]
465 483
Maximum voltage allowed Udc max [V] 1,000 (2) 1,000 (2)
Maximum current allowed Idc max [A 119 134
AC OUTPUT
Power rating Pac nom [kW] 55 65 (3)
Rated Output voltage Uac [V] 400 (±15%) 290 (4)
Current rating Iac nom [A] 79.4 130
Short circuit current (=1.5*In) Isc [A] 119 195
Grid frequency fac [Hz] 50 50
Harmonic distortion THD grid
[%] ≤ 3 ≤ 3
Power factor cosphi   0.99 0.99
EFFICIENCY RATING
Maximum efficiency   [%] 97.03 98.45
European efficiency (Euro-ETA)
[5, 10, 20, 30, 50, 75, 100% of Pac nom]
  [%] 96.6 (5)
[91.75; 95.00; 96.56; 96.96; 97.03; 96.77; 96.39]
97.9 (5)
[92.34; 96.20; 98.09; 98.34; 98.45; 98.07; 97.59]
GENERAL DATA
Protection class     IP33
IP33
Power switch on AC side
  yes no
Power switch on DC side     yes yes
Reverse polarity protection diodes
on DC side
    yes yes
Ground fault monitoring     optional optional
Overcurrent protection AC side   yes yes
DC side   no no
Overvoltage protection
AC side
  no no
DC side   optional optional
Remote plant monitoring     optional optional
Ground kit     optional(2) optional(2)
Ambient temperature range
(without power derating)
  [°C] from -10 °C to + 50 °C from -10 °C to + 50 °C
Requested air flow (input)   [m3/h] 2,000 2,000
Cooling     Thermostatically-controlled Thermostatically-controlled
Relative humidity of air   [%] from 5% to 85%
without condensation
from 5% to 85%
without condensation
Maximum altitude   [m] 1,000 m
(2,000 m with derating)
1,000 m
(2,000 m with derating)
Topology     With isolation transformer Without transformer
Dimensions:
Width x Height x Depth
  mm [inches] 800 x 1,600 x 800 [31.5 x 62.99 x 31.5]
Weight   kg [lbs] 550 [1,213] 330 [728]
(1) The recommended maximum power of the PV field is usually calculated considering a correction factor of 0.85: PDC max = PAC nom / 0.85 The correction factor may however vary, depending on the geographical location, ambient temperature and type of installation. (2) For string configurations, maximum recommended Vdc voltage 965V. If using the ground kit, maximum Vdc = 900V. (3) At 290V. (4) The acceptable range for the inverter output voltage is 270...400V (-15% +10%). This can be configured in the field on request. For each particular case the output voltage must be selected at the design stage, from within the accepted range. (5) Refers to the DC/AC conversion part, excluding auxiliary power supply.