Absolute reliability, robust design and high-quality components all add up to offer a system with a service life of over 25 years.
With above-average efficiency and a wide MPPT operating range, the Radius 250/270/330 k exploits diffused radiation to the full.
It operates at temperatures of up to 50°C without power derating and at a maximum voltage of 1000 Vdc to optimise plant design and reduce wiring between strings to a minimum.
All parts subject to wear are easily accessed from the front to facilitate maintenance and servicing.
The 250/270/330 k version is normally used in multi-inverter plants of over 1 megawatt connected to the medium voltage grid.
In these plants the TL (transformerless) version is ideal for reducing power loss to a minimum and achieving maximum efficiency.
Grid connection certifications
Italy: DK5940; Germany, France, Turkey, Greece and Czech Republic: DIN V VDE V 0126-1-1 (VDE V 0126-1-1):2006-02; Spain: RD 1663:2000; UK: G59/1:1991, G59/2:1991; Belgium: C10/11:2006; Israel AS 4777.2:2005, AS 4777.3:2005.
| APV250k-TL | APV250k-TL-M | APV270k-TL | APV270k-TL-M | APV330k-TL-M | |||
| DC INPUT | |||||||
| Recommended maximum PV power |
Pdc, max | [kW] | 300 (1) | 300 (1) | 333 (1) | 333 (1) | 412 (1) |
| MPPT voltage range | Udc | [V] | 483...850 | 483...850 | 483...850 | 483...850 | 500...850 |
| Minimum operating voltage | Udc min | [V] |
465 | 465 | 483 | 483 | 500 |
| Maximum voltage allowed | Udc max | [V] | 1,000 (2) | 1,000 (2) | 1,000 (2) | 1,000 (2) | 1,000 (2) |
| Maximum current allowed | Idc max | [A | 531 | 531 | 573 | 573 | 677 |
| AC OUTPUT | |||||||
| Power rating | Pac nom | [kW] | 250 (3) | 250 (3) | 270 (3) | 270 (3) | 330 (3) |
| Rated Output voltage | Uac | [V] | 290 (4) | 290 (4) | 290 (4) | 290 (4) | 320 (4) |
| Current rating | Iac nom | [A] | 497 | 497 | 540 | 540 | 600 |
| Short circuit current (=1.5*In) | Isc | [A] | 746 | 746 | 810 | 810 | 900 |
| Grid frequency | fac | [Hz] | 50 | 50 | 50 | 50 | 50 |
| Harmonic distortion | THD grid |
[%] | ≤ 3 | ≤ 3 | ≤ 3 | ≤ 3 | ≤ 3 |
| Power factor | cosphi | 0.99 | 0.99 | 0.99 | 0.99 | 0.99 | |
| EFFICIENCY RATING | |||||||
| Maximum efficiency | [%] | 97.65 | 97.65 | 97.65 | 97.65 | 97.65 | |
| European efficiency (Euro-ETA) [5, 10, 20, 30, 50, 75, 100% of Pac nom] |
[%] | 97.1 (5) [91.28; 94.99; 96.83; 97.37; 97.65; 97.59; 97.4] |
97,1 (6) [91.28; 94.99; 96.83; 97.37; 97.65; 97.59; 97.4] |
97.1 (5) [91.28; 94.99; 96.83; 97.37; 97.65; 97.59; 97.4] |
95,1 (6) [79.4; 89.0; 93.8; 95.4; 96,5; 96.8; 96.8] |
97.1 (6) [91.28; 94.99; 96.83; 97.37; 97.65; 97.59; 97.4] |
|
| GENERAL DATA | |||||||
| Protection class | IP20 | IP20 | IP20 | IP20 | IP20 | ||
| Power switch on AC side | optional | yes | optional | yes | yes | ||
| Power switch on DC side | yes | yes | yes | yes | yes | ||
| Reverse polarity protection diodes on DC side | yes | yes | yes | yes | yes | ||
| Ground fault monitoring | optional | optional | optional | optional | optional | ||
| Overcurrent protection | AC side | yes | yes | yes | yes | yes | |
| DC side |
no | yes (7) | no | yes (7) | yes (7) | ||
| Overvoltage protection |
AC side |
no | no | no | no | no | |
| DC side |
optional | optional | optional | optional | optional | ||
| Remote plant monitoring | optional | optional | optional | optional | optional | ||
| Ground kit | optional(2) | optional(2) | optional(2) | optional(2) | optional(2) | ||
| Ambient temperature range (without power derating) |
[°C] | from -10 °C to + 50 °C | from -10 °C to + 50 °C | from -10 °C to + 50 °C | from -10 °C to + 50 °C | from -10 °C to + 50 °C | |
| Requested air flow (input) | [m3/h] | 5,000 | 5,000 | 5,000 | 5,000 | 5,000 | |
| Cooling | Thermostatically-controlled | Thermostatically-controlled | Thermostatically-controlled | Thermostatically-controlled | Thermostatically-controlled | ||
| Relative humidity of air | [%] | from 5% to 85% without condensation | from 5% to 85% without condensation | from 5% to 85% without condensation | from 5% to 85% without condensation | from 5% to 85% without condensation | |
| Maximum altitude | [m] | 1,000 m (2,000 m with derating) |
1,000 m (2,000 m with derating) |
1,000 m (2,000 m with derating) |
1,000 m (2,000 m with derating) |
1,000 m (2,000 m with derating) |
|
| Topology | Without transformer | Without transformer | Without transformer | Without transformer | Without transformer | ||
| Size factor (*) | 0.83: PDC max = PAC nom / 0.83 | 0.83: PDC max = PAC nom / 0.83 | 0.81: PDC max = PAC nom / 0.81 | 0.81: PDC max = PAC nom / 0.81 | 0.8: PDC max = PAC nom / 0.8 | ||
| Dimensions: Width x Height x Depth |
mm [inches] | 1,400 x 2,250 x 800 [55.12 x 88.58 x 31.5] | |||||
| Weight | kg [lbs] | 965 [2127.5] | 1,000 [2204.6] | ||||
| (1) The recommended maximum power of the PV field is usually calculated considering a correction factor of "see table (*). The correction factor may however vary, depending on the geographical location, ambient temperature and type of installation. (2) For string configurations, maximum recommended Vdc voltage 965V. If using the ground kit, maximum Vdc = 900V. (3) At 290V (250k / 270k), 320V (330k) . (4) The acceptable range for the inverter output voltage is 270...400V (-15% +10%). This can be configured in the field on request. For each particular case the output voltage must be selected at the design stage, from within the accepted range. (6) Refers to the DC/AC conversion part, including auxiliary power supply. (7) For APV-...-IF versions only (5+5 inputs with 160A fuses) |