WorldWide (International)

APV 2300-2M-TL

PRINT
Inverter Home - APV 2300-2M-TL

Suitable for all indoor and outdoor environments, the Radius APV 2300-2M-TL has a strong and extremely compact structure and is capable of withstanding particularly severe weather conditions.
This solution features highly reliable technology deriving from the use of advanced components, good heat dissipation on the back to prevent overheating and the absence of moving parts such as fans.

Grid connection certifications
Italy: DK5940; Spain: RD1663 (declaration); Germany and France VDE 0126; UK: G83 (declaration); USA: UL1741, IEEE1547, CSA C22.2 No.107.1,FCC Part15 (Class B).

Choose language:
APV 2300-2M-TL APV 2300-2M-TL-US*
DC INPUT
Recommended maximum PV power Pdc, max [kWp] 2.3 2.3
MPPT voltage range Udc [V] 120-450 120-450
Minimum operating voltage Udc min [V] 120 120
Maximum voltage allowed Udc max [V] 500 500
Maximum input current Isc max [A] 15 10
Max number of parallel strings - 2
Number MPPT 1 1
Current rating for each MPPT channel Idc nom [A] 12 10
AC OUTPUT
Maximum power P max [kW] 2.2 2.0
Power rating Pac nom [kW] 2 1.8@208Vac
2.0@240/277Vac
Grid voltage (1ph) Uac [V] 200 - 250 208, 240, 277
Maximum current Iac max [A] 11 9.7 / 9.4 / 8.2
Short circuit current, (=1.5*In) Isc [A] 13 15
Grid frequency fac [Hz] 50/60 (± 5Hz) 60 (59.3 to 60.5)
Harmonic distortion THD grid [%] < 3% < 3%
Power factor (settable) cosphi 1 > 0.99
EFFICIENCY RATING
Maximum efficiency [%] 97 97.5
European efficiency (Euro ETA) [%] 96 -
[5, 10, 20, 30, 50, 100% of Pac nom]
[%] [93.85%; 95.35%; 96.51%; 96.83%;
96.5%; 96%]
-
CEC efficiency [%] - 96.5
MPPT efficiency [%] - 99.5
GENERAL DATA
Protection class IP65 NEMA 3R
Power switch
AC side no no
DC side yes yes
Reverse polarity protection diodes
on DC side
yes yes
Ground fault monitoring yes yes
Overvoltage protection AC side yes yes
DC side yes yes
Remote inverter monitoring optional
Ambient temperature range °C
[°F]
-25°C … +60°C [-13°F ...+140°F],
with power derating above +50°C [+122°F]
-25°C … +60°C [-13°F ...+140°F],
with power derating above +45°C [+113°F]
Cooling Controlled cooling
Relative humidity of air [%] 0 … 95
without condensation
Maximum altitude [m] up to 2000 metres
(without power derating)
Topology Without isolation transformer (TL)
Dimensions: Width x Height x Depth mm [inches] 362 x 329 x 131.5 360 x 465 x 165
[14.17 x 18.3 x 6.5]
Weight kg [lbs] 11.7 15.4
[33.95]
* Model for USA